3200B Series
Electrical Test Equipment Calibrator


Introduction

The industry leading 3200B series provides by far the fastest and safest solution for calibration of Loop, RCD, PAT's and insulation testers.

By using the 3200B series, calibration time can be drastically reduced, while superior accuracy means that cost-effective calibration can be put easily in to practice, ensuring a fast return on investment.

FAST, EFFICIENT AND SAFE ELECTRICAL TEST EQUIPMENT CALIBRATION

The industry leading 3200A series provides by far the fastest and safest solution for calibration of Loop, RCD, PAT's and insulation testers. 

Traditional testing practices require many pieces of test equipment and exposure to hazardous voltages, with a typical multifunction tester taking up to 45 minutes to test.

Using the 3200A, calibration time can be dramatically reduced to under 15 minutes, all while increasing safety. Cost effective calibration can be put into practice easily, providing a fast return on investment.

pat testing calibration electrical calibration equipment

A dedicated localized mains socket on the front panel provides direct connect for Loop and RCD testers, removing the need to make connections to the mains/line voltage using 4mm type test leads and crocodile clips. This important safety feature eliminates the risk of shock to the engineer as connections are made with standard mains/line plugs.

SUPERIOR ACCURACY

Electric tester tools are continually improving, adding ranges, functions and getting ever more accurate.

The 3200B/9200B provides suitable accuracy for calibration of even the most accurate electricians test tools whilst remaining competitively priced and easy to use. The 3200A/9200A achieve a test uncertainty ratio (TUR) of 4:1 when calibrating electricians test tools to provide confidence whilst calibrating.

17th edition test equipment electric tester


PORTABILITY

The 3200A and 9200A have been designed to have short warm up times for the ultimate in portability. The 3200A/9200A can be up and testing in less than 20 minutes, and are light enough to be carried everywhere.

 

3200B

Benchtop

Continuity Resistance Standard Accuracy (Best 1 Year Accuracy)
0.2Ω - 1kΩ (1% (0.25% Option))
Continuity Current (Best 1 Year Accuracy)
0 - 320mA (1.3%)
Insulation Test Voltage Measurement (Best 1 Year Accuracy)
0Ω - 2GΩ (0.3% (0.1% Option))
AC Voltage Output (Best 1 Year Accuracy)
100V - 400V (0.2%)
Loop Resistance (Best 1 Year Accuracy)
3mA - 3A (1.2%)
PAT Earth Bond Resistance (Best 1 Year Accuracy)
0.05Ω - 1kΩ (0.5%)
PAT Earth Bond Current Measurement (Best 1 Year Accuracy)
100mA - 30A (1.5%)
PAT Insulation Resistance (Best 1 Year Accuracy)
0Ω - 2GΩ (0.3% (0.1% Option))
PAT Leakage Current (Best 1 Year Accuracy)
2mA - 7.7mA (1.5%)
PAT Leakage Test Voltage (Best 1 Year Accuracy)
100V - 300V (1.5%)

9200B

Portable

Continuity Resistance Standard Accuracy (Best 1 Year Accuracy)
0.2Ω - 1kΩ (1% (0.25% Option))
Continuity Current (Best 1 Year Accuracy)
0 - 320mA (1.3%)
Insulation Test Voltage Measurement (Best 1 Year Accuracy)
0Ω - 2GΩ (0.3% (0.1% Option))
AC Voltage Output (Best 1 Year Accuracy)
100V - 400V (0.2%)
Loop Resistance (Best 1 Year Accuracy)
3mA - 3A (1.2%)
PAT Earth Bond Resistance (Best 1 Year Accuracy)
0.05Ω - 1kΩ (0.5%)
PAT Earth Bond Current Measurement (Best 1 Year Accuracy)
100mA - 30A (1.5%)
PAT Insulation Resistance (Best 1 Year Accuracy)
0Ω - 2GΩ (0.3% (0.1% Option))
PAT Leakage Current (Best 1 Year Accuracy)
2mA - 7.7mA (1.5%)
PAT Leakage Test Voltage (Best 1 Year Accuracy)
100V - 300V (1.5%)
Breakdown Adapter

Breakdown Adapter

The BreakD option allows the 3200 to calibrate both voltage output and current measurements of HiPot and Breakdown testers up to 12kV AC/DC

EXT HV

EXT HV

The EXT HV Adapter allows insulation testers with test voltages of up to 15kV to be used with the 3200. Resistances of up to 1TOhm are available.