4000 Series
Advanced Multiproduct Calibrator


Introduction

The 4000 Series is aimed at laboratories, manufacturers and design facilities requiring a wide range of outputs with accuracies up to 8ppm.

The 4000 Series builds on the trusted reliability of the 3000A series, offering an updated user interface accessed through a large 7" capacitive touch screen to enable advanced functionality, including a built-in procedure mode and inbuilt connection prompts to minimise errors.

Procedures can be loaded into the 4000 Series via USB memory stick, with results stored for integration back into ProCal software. The 4000 Series also provides USB printer connectivity as standard, supporting a wide range of PCL compatible printers. Reports can be printed directly from the calibrator - ideal for in-situ or on-site applications.

4000 Series - Direct Ohms Selection
In this short video we demonstrate the latest updates to the 4000 series. The addition of new function keys enable direct access to the decade passive resistors enabling outputs to be directly accessed with a single touch of the screen.
4000 Series - Automated Verification
An example of the automated verification functionality using a Transmille 8081 precision multimeter.
4000 Series - Procedure Mode
Demonstration of the built-in procedure mode using a typical multimeter.
Advanced Oscilloscope Calibration Functionality

Expanding the outputs offered by the 3000A series, the 4000 series provides an advanced oscilloscope calibration option with bandwidth calibration of up to 6 GHz with variable level. This expands the calibration workload to include spectrum analysers and high bandwidth oscilloscopes.


To maintain confidence in your equipment, simply connect an 8000 series digital multimeter to the rear of the unit and enter 'self-calibration mode'. The 4000 series will then proceed to measure its outputs automatically and generate a test report which can be exported to a USB memory stick for analysis on a computer, and print a test report via a USB printer for maintaining records.


Software Compatibility

As with all Transmille products, compatibility with ProCal calibration software is guaranteed. Existing procedures will not need to be re-written due to Transmille's unique implementation of flexible standards support where procedures are written around the UUT not the standard.

4010

DC Voltage (Best 1 Year Total Accuracy)
0 - ±1025V (±8ppm)
DC Current (Best 1 Year Total Accuracy)
0 - 30A (±50ppm)
AC Voltage (Best 1 Year Total Accuracy)
20mV - 1000V, 10Hz - 1MHz (0.015%)
AC Current (Best 1 Year Total Accuracy)
20uA - 30A, 10Hz - 30kHz (0.04%)
Resistance (Passive) (Best 1 Year Total Accuracy)
0 Ohms - 1 GOhm (18ppm)
Capacitance (Passive) (Best 1 Year Total Accuracy)
1nF - 10uF (0.25%)
Frequency (Best 1 Year Total Accuracy)
1Hz - 10MHz (1ppm)
Temperature (Thermocouple) (Best 1 Year Total Accuracy)
J / K / T / R / S / B / U / N / E / L / U / C / 10uV°C (±0.09°C)
Resistance (Simulated) (Best 1 Year Total Accuracy)
0 Ohms - 1 GOhm (100ppm)

4015

DC Voltage (Best 1 Year Total Accuracy)
0 - ±1025V (±15ppm)
DC Current (Best 1 Year Total Accuracy)
0 - 30A (±50ppm)
AC Voltage (Best 1 Year Total Accuracy)
20mV - 1000V, 10Hz - 500kHz (0.015%)
AC Current (Best 1 Year Total Accuracy)
20uA - 30A, 10Hz - 30kHz (0.04%)
Resistance (Passive) (Best 1 Year Total Accuracy)
0 Ohms - 1 GOhm (40ppm)
Capacitance (Passive) (Best 1 Year Total Accuracy)
1nF - 10uF (0.25%)
Frequency (Best 1 Year Total Accuracy)
1Hz - 10MHz (10ppm (1ppm Option))
Temperature (Thermocouple) (Best 1 Year Total Accuracy)
J / K / T / R / S / B / U / N / E / L / U / C / 10uV°C (±0.09°C)
Resistance (Simulated) (Best 1 Year Total Accuracy)
0 Ohms - 1 GOhm (100ppm)
Option SYS

Option SYS

Option SYS incorporates our most popular options at discounted price

Option FRQ

Option FRQ

For calibration of high accuracy frequency counters, a 1ppm high stability frequency output is available

Option PRT

Option PRT

Precision 4 Wire PRT output for guaranteed compatibility with both DC meters and AC bridges

Option IND

Option IND

For full calibration of LCR meters, an inductance output is required. Option IND adds 8 fixed inductance values to enable complete calibration

Option PWRDDS

Option PWRDDS

Option PWRDDS expands on the functionality of PWRSINE by adding the ability to simulate harmonics, distortion, dropouts and flicker for calibration of power meters with power quality functions

Option PWRSINE

Option PWRSINE

Enables calibration of power and wattmeters, with a dynamically controlled phase relationship between voltage and current outputs.

Option GPIB

Option GPIB

Additional GPIB / IEEE 488 interface for connecting into existing systems

Option SCP250

Option SCP250

Providing calibration for oscilloscopes to 250Mhz bandwidth

Option SCP350

Option SCP350

Providing calibration for oscilloscopes to 350Mhz bandwidth

Option SCP600

Option SCP600

Providing calibration for oscilloscopes to 600Mhz bandwidth

Rack Mount System

Rack Mount System

For integration in to mobile test systems, or permanent installation in a laboratory, a 19" rack system is provided

USB To RS232 Interface Lead

USB To RS232 Interface Lead

Add RS232 support to modern computers and laptops

3000 Lead

3000 Lead

A comprehensive set of test leads providing every connection required for typical measurements

TPMxx Pressure Modules

TPMxx Pressure Modules

A range of external pressure modules for use with Transmille products, designed to extend capabilities from 1 PSI to 10,000 PSI

EA001A Thermocouple Simulation & Measurement Adapter

EA001A Thermocouple Simulation & Measurement Adapter

A superior thermocouple simulation/measurement option, using a unique external adapter.

EA002 2/10/50 Turn Coil Adapter

EA002 2/10/50 Turn Coil Adapter

Calibrate clamp meters at up to 1500A using the EA002 clamp meter. A unique design enables clamps of all sizes to be used, while minimising errors due to alignment

EA003 Optical Tachometer Calibration Adapter

EA003 Optical Tachometer Calibration Adapter

Instantly add the ability to calibrate tachometers to 60,000 RPM by adding the EA003 to your calibrator

EA008 pA/High Resistance Measurement Adapter

EA008 pA/High Resistance Measurement Adapter

Adds measurement capability to 1pA resolution, and measures high value resistors to 1TOhm using the calibrator as a precision DC voltage source

EA013 picoamp Source Adapter

EA013 picoamp Source Adapter

As multimeters add more accurate low current ranges, traditional multi-product calibrators lack the precision and noise level for accurate calibration. With the EA013 pA source adapter, calibration of these instruments becomes simple

EA014 Torque Measurement Adapter

EA014 Torque Measurement Adapter

Extend your laboratory's capabilities with the ability to calibrate torque screwdrivers and much more

EA015 Multifunction Workstation Adapter

EA015 Multifunction Workstation Adapter

Combining Transmille's most popular options, the EA015 provides a cost-effective method of increasing the workload coverage of Transmille calibrators

EA016 Humidity & Temperature Measurement Adapter

EA016 Humidity & Temperature Measurement Adapter

Measure environmental factors both on site and in the laboratory

EA017 4 Channel Oscilloscope Test Head Adapter

EA017 4 Channel Oscilloscope Test Head Adapter

Automate calibration of 4 channel oscilloscopes with automised switching of channels with the EA017 adapter

EA3012A 100A DC/70A AC Transconductance Amplifier

EA3012A 100A DC/70A AC Transconductance Amplifier

Calibrate low value high current shunts up to 100A and clamp meters up to 2000A using the EA3012A Transconductance Amplifier

EA3023 3A/63V Power Supply Calibration Adapter

EA3023 3A/63V Power Supply Calibration Adapter

Increase your laboratory capability with the ability to calibrate power supplies up to 3A/63V

EA3024 AC/DC Kilovolt Amplifier

EA3024 AC/DC Kilovolt Amplifier

A dedicated kilovolt amplifier ads the capability to calibrate high voltage probes and dividers at up to 10kV DC / 5kV AC

EA3025A 60A/100V Power Supply Calibration Adapter

EA3025A 60A/100V Power Supply Calibration Adapter

Increase your laboratories workload coverage to include high current power supplies with up to 60A/100V outputs