8000 series
Precision Multimeters


Introduction

The 8000 series digital multimeter represent another breakthrough in measurement technology, leaping ahead of older multimeter design using the latest in components and multi processor digital design.

The heart of any precision instrument is its analogue design, and with the experience and knowledge gained by Transmille since 1997 with the design of multiproduct calibrators all of this knowledge has been implemented in the 8000 series.

By bringing together the latest technology in both analogue and digital design, Transmille have significantly reduced the parts count and complexity of precision multimeters, achieving unrivalled performance and functionality at a breakthrough price/performance ratio to meet the requirements of modern day laboratories.

The 8000 Series offers unmatched functionality with unique features such as High Current measurement up to 30A without the need for external current shunts.


Universal Connectivity

The 8000 Series is unique in offering 4 interfaces ensuring connectivity with any existing system. USB, RS232 (Serial), GPIB (IEEE-488) and Ethernet (RJ45) are included as standard on all 8000 series multimeters. 

8071

Multimeter

DC Voltage (Best 1 Year Total Accuracy)
0 to ±1000V (±9ppm)
AC Voltage (Best 1 Year Total Accuracy)
±1uV - ±1050V, 10Hz - 100kHz (±0.06%)
DC Current (Best 1 Year Total Accuracy)
±100uA - ±30A (±25ppm)
AC Current (Best 1 Year Total Accuracy)
±100uA - 30A (±0.08%)
Resistance (Best 1 Year Total Accuracy)
0 - 10 MΩ (±20ppm)
Temperature (PRT) (Best 1 Year Total Accuracy)
Temperature (Thermocouple) (Best 1 Year Total Accuracy)

8080

Multimeter

DC Voltage (Best 1 Year Total Accuracy)
0 to ±1000V (±4ppm)
AC Voltage (Best 1 Year Total Accuracy)
±1uV - ±1050V, 10Hz - 1MHz (±0.02%)
DC Current (Best 1 Year Total Accuracy)
±100uA - 30A (±7pp)
AC Current (Best 1 Year Total Accuracy)
±100uA - 30A (±0.03%)
Resistance (Best 1 Year Total Accuracy)
0 - 10 MΩ (±8ppm)
Temperature (PRT) (Best 1 Year Total Accuracy)
Temperature (Thermocouple) (Best 1 Year Total Accuracy)

8081

Multimeter

DC Voltage (Best 1 Year Total Accuracy)
0 to ±1000V (±4ppm)
AC Voltage (Best 1 Year Total Accuracy)
±0.1uV - ±1050V, 10Hz - 1MHz (±0.02%)
DC Current (Best 1 Year Total Accuracy)
±10nA - 30A (±7pp)
AC Current (Best 1 Year Total Accuracy)
±100uA - 30A (±0.03%)
Resistance (Best 1 Year Total Accuracy)
0 to 1 TΩ (±8ppm)
Temperature (PRT) (Best 1 Year Total Accuracy)
PRT -200°C - 660°C
Temperature (Thermocouple) (Best 1 Year Total Accuracy)
K / J / B / E / R / S / N / T (±0.08°C)

8000 Series FAQ

Transmille's EA001/EA001A has been designed to minimise typical errors associated with calibration of thermocouple meters that are ignored by other designs.

By making the thermocouple option external, the low voltage output (in the order of 0mV to 100mV, with accuracies in the microvolt level required for accurate simulation) is away from any heat generating components in the calibrator therefore reducing any localised thermal EMF effects.

The inclusion of a Thermocouple plug removes the need to find compensation cables of the correct type, which is a considerable source of error. If the wrong type of compensation cable (for example, when simulating a K type thermocouple, a J type compensating cable) is used there will be a significant error introduced through use of the wrong cable.

Finally, a temperature measurement is conducted at the connection with the UUT, in the thermocouple plug itself. This is measuring the cold junction as close to the internal measurement of the UUT as possible, removing localised differences in temperature.

For further information on the design of our thermocouple option, please view our YouTube video HERE.