Instantly add the ability to calibrate tachometers to 60,000 RPM by adding the EA003 to your calibrator
- High-intensity LED light source
- Direct keyboard input in RPM
- Control via ProCal for fully automated calibration
- Output range from 60 to 60,000 RPM
Adds measurement capability to 1pA resolution, and measures high value resistors to 1TOhm using the calibrator as a precision DC voltage source
- Accurate current measurement down to 1pA resolution
- Ideal for high value resistance measurements up to 1 TOhm
- High resistance measurement voltages up to 1000V
- 5 current measurement rnages from 10nA to 100uA
- Control directly from the calibrator front panel or use with ProCal software
External
As multimeters add more accurate low current ranges, traditional multi-product calibrators lack the precision and noise level for accurate calibration. With the EA013 pA source adapter, calibration of these instruments becomes simple
- Ideal for calibration of electrometer instruments
- Source accurate current down to picoamp levels
- Low open circuit compliance voltage
- Safe to use on sensitive input circuits
- Controlled directly from the calibrator front panel or via supplied software
- Compatible with ProCal for full measurement automation
External
Extend your laboratory's capabilities with the ability to calibrate torque screwdrivers and much more
Combining Transmille's most popular options, the EA015 provides a cost-effective method of increasing the workload coverage of Transmille calibrators
- Insulation Testers
- Continuity Testers
- Optical Tachometers
- Thermocouple Meters
- Clamp Meters
- Source functions of process control meters
Measure environmental factors both on site and in the laboratory
- Humidity measurement from 10% to 90%
- Temperature measurement from 0°C to 50°C
Automate calibration of 4 channel oscilloscopes with automised switching of channels with the EA017 adapter
- 4 Output channels for automating oscilloscope calibration
- Minimises lead changing when calibrating oscilloscopes
- Choose between direct or buffered outputs for amplitude calibration
Enables calibration of source functions of Process Control instruments including voltage, current and resistance.
- Extends workload of 1000 Series Calibrators
- Measure source functions from process control instruments
- Voltages up to 30V
- Currents up to 30A
- 2 and 4 wire resistance up to 10 kOhms
- 24V loop supply
Calibrate low value high current shunts up to 100A and clamp meters up to 2000A using the EA3012A Transconductance Amplifier
- 100 DC/70A AC up to 400Hz
- Stackable for higher currents
- Low-noise ultra linear MOSFET technology
- Controlled directly via front panel of calibrator
- Automation through ProCal software
- Ideal for calibrating high current shunts, meters and clamp meters
Increase your laboratory capability with the ability to calibrate power supplies up to 3A/63V
- Measures voltage up to 63V
- Active current load to 3A
- Calculates output resistance of a power supply for complete calibration
External
A dedicated kilovolt amplifier ads the capability to calibrate high voltage probes and dividers at up to 10kV DC / 5kV AC
- Outputs from 1kV to 10kV DC
- Outputs from 1kV to 5kV AC at up to 60Hz
- Operated using supplied software or via ProCal calibration software
Increase your laboratories workload coverage to include high current power supplies with up to 60A/100V outputs.
- Easy to use, low cost solution
- Accurate, stable electronic load
- Minimises equipment required for calibration