Legacy Products
Precision Multimeters
- AC / DC Voltage Sources
- AC / DC Current Sources
- Decade Boxes
- High Value Resistance Standards (up to 1TOhm)
- Multiproduct Calibrators
- Multifunction Calibrators
- Process Control Calibrators (Source Functions)
- Thermocouple Sources
External
Designed for transporting your multimeter through couriers and harsh environments, with custom laser cut foam for holding units securely
Legacy Products
Frequency Source/Measurement
- Frequency source to 1Ghz with dedicated 10MHz direct GPS output
- Measurement to 1GHz
- Integrated GPS reference for the ultimate in accuracy
- A-B Phase output for verification of phase measurement functions of counter-timers
- Dual VFD displays for convenience
Legacy Products
Frequency Source/Measurement
- Frequency source to 1Ghz with dedicated 10MHz direct GPS output
- Measurement to 1GHz
- Integrated GPS reference for the ultimate in accuracy
- A-B Phase output for verification of phase measurement functions of counter-timers
- High Resolution, Colour 7
- Integrated GPS Data Logging for Traceability
External
The BreakD option allows the 3200 to calibrate both voltage output and current measurements of HiPot and Breakdown testers up to 12kV AC/DC
- 4 voltage ranges: 3kV & 12kV, AC and DC Voltage
- 9 Load Resistors/Current Ranges: 50kOhms (20mA) to 20MOhms (20uA) @ 1kV
A superior thermocouple simulation/measurement option, using a unique external adapter.
- Offers fast and accurate calibration of thermocouple meters
- Uses an innovative external measurement of cold junction temperature for ultimate accuracy
- Utilising a thermocouple plug removes the requirement for expensive thermocouple compensation cable
External
Calibrate clamp meters at up to 1500A using the EA002 clamp meter. A unique design enables clamps of all sizes to be used, while minimising errors due to alignment
- Calibrates clamp meters up to 1500A (30A input)
- 2/10/50 Turn Coils
- High accuracy AC/DC design, with minimal errors due to alignment
- Wide range of clamp sizes covered, from 10mm jaw diameter to larger clamps
- Alignment table included for accurate and repeatable readings
Instantly add the ability to calibrate tachometers to 60,000 RPM by adding the EA003 to your calibrator
- High-intensity LED light source
- Direct keyboard input in RPM
- Control via ProCal for fully automated calibration
- Output range from 60 to 60,000 RPM
Adds measurement capability to 1pA resolution, and measures high value resistors to 1TOhm using the calibrator as a precision DC voltage source
- Accurate current measurement down to 1pA resolution
- Ideal for high value resistance measurements up to 1 TOhm
- High resistance measurement voltages up to 1000V
- 5 current measurement rnages from 10nA to 100uA
- Control directly from the calibrator front panel or use with ProCal software
External
As multimeters add more accurate low current ranges, traditional multi-product calibrators lack the precision and noise level for accurate calibration. With the EA013 pA source adapter, calibration of these instruments becomes simple
- Ideal for calibration of electrometer instruments
- Source accurate current down to picoamp levels
- Low open circuit compliance voltage
- Safe to use on sensitive input circuits
- Controlled directly from the calibrator front panel or via supplied software
- Compatible with ProCal for full measurement automation
External
Extend your laboratory's capabilities with the ability to calibrate torque screwdrivers and much more