2090 Programmable Decade Resistance Box

Precision References and Standards

  • 0 - 10 kOhm
  • RS232 Interface
  • Front panel display & controls
  • 0.1% Accuracy (0.01% Accuracy option)
  • 1 Watt power rating
  • Virtual Front Panel software for PC
More Info Global Distributors

2090

Instantly add the ability to calibrate tachometers to 60,000 RPM by adding the EA003 to your calibrator

  • High-intensity LED light source
  • Direct keyboard input in RPM
  • Control via ProCal for fully automated calibration
  • Output range from 60 to 60,000 RPM

Adds measurement capability to 1pA resolution, and measures high value resistors to 1TOhm using the calibrator as a precision DC voltage source

  • Accurate current measurement down to 1pA resolution
  • Ideal for high value resistance measurements up to 1 TOhm
  • High resistance measurement voltages up to 1000V
  • 5 current measurement rnages from 10nA to 100uA
  • Control directly from the calibrator front panel or use with ProCal software

As multimeters add more accurate low current ranges, traditional multi-product calibrators lack the precision and noise level for accurate calibration. With the EA013 pA source adapter, calibration of these instruments becomes simple

  • Ideal for calibration of electrometer instruments
  • Source accurate current down to picoamp levels
  • Low open circuit compliance voltage
  • Safe to use on sensitive input circuits
  • Controlled directly from the calibrator front panel or via supplied software
  • Compatible with ProCal for full measurement automation

Extend your laboratory's capabilities with the ability to calibrate torque screwdrivers and much more

Combining Transmille's most popular options, the EA015 provides a cost-effective method of increasing the workload coverage of Transmille calibrators

  • Insulation Testers
  • Continuity Testers
  • Optical Tachometers
  • Thermocouple Meters
  • Clamp Meters
  • Source functions of process control meters

Measure environmental factors both on site and in the laboratory

  • Humidity measurement from 10% to 90%
  • Temperature measurement from 0°C to 50°C

Automate calibration of 4 channel oscilloscopes with automised switching of channels with the EA017 adapter

  • 4 Output channels for automating oscilloscope calibration
  • Minimises lead changing when calibrating oscilloscopes
  • Choose between direct or buffered outputs for amplitude calibration

Enables calibration of source functions of Process Control instruments including voltage, current and resistance.

  • Extends workload of 1000 Series Calibrators
  • Measure source functions from process control instruments
  • Voltages up to 30V
  • Currents up to 30A
  • 2 and 4 wire resistance up to 10 kOhms
  • 24V loop supply

Calibrate low value high current shunts up to 100A and clamp meters up to 2000A using the EA3012A Transconductance Amplifier

  • 100 DC/70A AC up to 400Hz
  • Stackable for higher currents
  • Low-noise ultra linear MOSFET technology
  • Controlled directly via front panel of calibrator
  • Automation through ProCal software
  • Ideal for calibrating high current shunts, meters and clamp meters

Increase your laboratory capability with the ability to calibrate power supplies up to 3A/63V

  • Measures voltage up to 63V
  • Active current load to 3A
  • Calculates output resistance of a power supply for complete calibration

A dedicated kilovolt amplifier ads the capability to calibrate high voltage probes and dividers at up to 10kV DC / 5kV AC

  • Outputs from 1kV to 10kV DC
  • Outputs from 1kV to 5kV AC at up to 60Hz
  • Operated using supplied software or via ProCal calibration software

Increase your laboratories workload coverage to include high current power supplies with up to 60A/100V outputs.

  • Easy to use, low cost solution
  • Accurate, stable electronic load
  • Minimises equipment required for calibration