AC/DC Shunts

Precision References And Standards

Transmille offer a set of current shunts enabling measurement of current from 1mA through to 100A. Each shunt develops 0.7V at nominal full scale, enabling a wide range of multimeters to be used without loss of resolution due to changing range.

  • Shunt values for measurements between 1mA to 100A
  • AC/DC differences from 1ppm
  • Simplifies precision calibration of calibrators and current sources
  • Low inductance & capacitance flat frequency response
  • From DC to 30kHz
  • Can be used with a precision multimeter or an AC measurement standard
More Info Global Distributors

3000HR Precision Resistance Standard

Precision References and Standards

  • Electrometer currents to 10nA
  • Traceable to 1 GOhm standard
  • Resistance from 1 Mohm to 100 Gohm
More Info Global Distributors

3000HR

3000RS Precision Resistance Standard

Precision References and Standards

  • Decade resistances from 1 Ohm to 10MOhm
  • Annual stabilities of better than 5ppm
  • Temperature co-efficients as low as 0.1ppm/°C
  • Precision decade resistance reference
More Info Global Distributors

3000RS

3000ZR Precision Zener Reference

Precision References & Standards

  • 4 Banks of 10V and 1.018V outputs
  • Stability of better than 2ppm/year
  • Internal battery backup for transportation
More Info Global Distributors

3000ZR

3000AC Voltage Reference

Precision References and Standards

  • Calculable AC voltage reference source
  • Traceable to any DC voltage multimeter with suitable accuracies
  • Accuracy in the order of 10ppm
  • AC voltage with frequency to 1kHz
More Info Global Distributors

3000AC

3000CS Precision Current Shunt

Precision References & Standards

  • Precision current shunt array
  • 1 year stability of up to 5ppm
  • Temperature coefficients of less than 0.6ppm/°C
  • Values 10mA through to 10A
  • 4-Wire PT100 Output
More Info Global Distributors

3000CS

The BreakD option allows the 3200 to calibrate both voltage output and current measurements of HiPot and Breakdown testers up to 12kV AC/DC

  • 4 voltage ranges: 3kV & 12kV, AC and DC Voltage
  • 9 Load Resistors/Current Ranges: 50kOhms (20mA) to 20MOhms (20uA) @ 1kV

Combining Transmille's most popular options, the EA015 provides a cost-effective method of increasing the workload coverage of Transmille calibrators

  • Insulation Testers
  • Continuity Testers
  • Optical Tachometers
  • Thermocouple Meters
  • Clamp Meters