2000 Series

Multi-Product Calirbaitor

The 2000 Series Calibrators use the latest technology from the reference source to the front panel design to give outstanding accuracy and performance. The latest foil resistors and an ultra linear D/A design ensures stable, low noise outputs suitable for today’s calibration requirements.

  • AC/DC Voltage1000V
  • AC/DC Current to 20A
  • 2&4Wire Resistance to1GR
  • Capacitance to 100uF
  • Power Calibration Option
  • Oscilloscope Calibration Option

ASK AN EXPERT

Information

Description

The 2000 Series Calibrators use the latest technology from the reference source to the front panel design to give outstanding accuracy and performance. The latest foil resistors and an ultra linear D/A design ensures stable, low noise outputs suitable for today’s calibration requirements.

Developed for both laboratory and on site calibration, the 2000 series packs full calibration functionality into a briefcase size box. After a fast warm up time the 2000 series is ready to start work. The modern circuit design and use of low temperature coefficient components combined with the internal temperature monitoring and compensation allow the 2000 series calibrators to be used in uncontrolled environments.

Calibrates, analogue &digital multimeters, digital thermometers, optical tachometers, frequency counters, chart recorders, low ohm meters, power meters, clamp meters, oscilloscopes, rlc meters, power supplies

The World’s First Truly Portable Calibration System

  • Ideal for On-Site calibration
  • Ultra portable (12.5kgs)
  • Custom Carry Case with Front & Rear access
  • Laptop extender case for a complete system solution

The world’s only truly portable calibration system enables for the first time
calibration work to be performed in-situ saving both time and inconvenience
for military, marine, aerospace and industrial applications.
The small footprint of the calibrator makes it ideal for use in confined spaces. Operation from within the custom carry case, together with a laptop PC eliminates lengthy setup delays.

2000 Series SPECIFICATIONS

2000 Series SPECIFICATIONS

2006

2041A

2050

DC VOLTAGE
Best 1 Year Accuracy

2041A

0 ± 1000V
± 25ppm

2050

0 ± 1000V
± 50ppm

AC VOLTAGE
Best 1 Year Accuracy

2041A

0 - 1000V
± 0.03%

2050

0 - 1000V

DC CURRENT
Best 1 Year Accuracy

2041A

0 - ± 20A
± 20ppm

2050

0 ± 20A

AC CURRENT
Best 1 Year Accuracy

2041A

0 - 20A
± 0.06%

2050

0 - 20A

2/4 WIRE RESISTANCE
Best 1 Year Accuracy

2041A

0 - 1 Gohm
± 40ppm

2050

0 - 10MΩ

CAPCITANCE
Best 1 Year Accuracy

2041A

1nF - 100uF
± 0.25%

2050

1nF - 1uF

2006

2041A

2050

2006A Resources

2006A Resources

2041A Resources

2041A Resources

2050 Resources

2050 Resources

Options & Accessories

Adds measurement capability to 1pA resolution, and measures high value resistors to 1TOhm using the calibrator as a precision DC voltage source

  • Accurate current measurement down to 1pA resolution
  • Ideal for high value resistance measurements up to 1 TOhm
  • High resistance measurement voltages up to 1000V
  • 5 current measurement rnages from 10nA to 100uA
  • Control directly from the calibrator front panel or use with ProCal software

As multimeters add more accurate low current ranges, traditional multi-product calibrators lack the precision and noise level for accurate calibration. With the EA013 pA source adapter, calibration of these instruments becomes simple

  • Ideal for calibration of electrometer instruments
  • Source accurate current down to picoamp levels
  • Low open circuit compliance voltage
  • Safe to use on sensitive input circuits
  • Controlled directly from the calibrator front panel or via supplied software
  • Compatible with ProCal for full measurement automation

Extend your laboratory's capabilities with the ability to calibrate torque screwdrivers and much more

Combining Transmille's most popular options, the EA015 provides a cost-effective method of increasing the workload coverage of Transmille calibrators

  • Insulation Testers
  • Continuity Testers
  • Optical Tachometers
  • Thermocouple Meters
  • Clamp Meters
  • Source functions of process control meters

Measure environmental factors both on site and in the laboratory

  • Humidity measurement from 10% to 90%
  • Temperature measurement from 0°C to 50°C

Automate calibration of 4 channel oscilloscopes with automised switching of channels with the EA017 adapter

  • 4 Output channels for automating oscilloscope calibration
  • Minimises lead changing when calibrating oscilloscopes
  • Choose between direct or buffered outputs for amplitude calibration

Enables calibration of source functions of Process Control instruments including voltage, current and resistance.

  • Extends workload of 1000 Series Calibrators
  • Measure source functions from process control instruments
  • Voltages up to 30V
  • Currents up to 30A
  • 2 and 4 wire resistance up to 10 kOhms
  • 24V loop supply

Calibrate low value high current shunts up to 100A and clamp meters up to 2000A using the EA3012A Transconductance Amplifier

  • 100 DC/70A AC up to 400Hz
  • Stackable for higher currents
  • Low-noise ultra linear MOSFET technology
  • Controlled directly via front panel of calibrator
  • Automation through ProCal software
  • Ideal for calibrating high current shunts, meters and clamp meters

Increase your laboratory capability with the ability to calibrate power supplies up to 3A/63V

  • Measures voltage up to 63V
  • Active current load to 3A
  • Calculates output resistance of a power supply for complete calibration

Increase your laboratories workload coverage to include high current power supplies with up to 60A/100V outputs.

  • Easy to use, low cost solution
  • Accurate, stable electronic load
  • Minimises equipment required for calibration

External

EXT HV

The EXT HV Adapter allows insulation testers with test voltages of up to 15kV to be used with the 3200. Resistances of up to 1TOhm are available.

  • Calibrates insulation testers at voltages up to 15kV
  • Simulates resistances up to 1TOhm
  • External Option, can be purchased for use with pre-existing equipment

Internal

Option FRQ

For calibration of high accuracy frequency counters, a 1ppm high stability frequency output is available on 3000/4000 only.