4000 Series
Advanced Multiproduct Calibrator
The 4000 Series is aimed at laboratories, manufacturers and design facilities requiring a wide range of outputs with accuracies up to 8ppm.
The 4000 Series builds on the trusted reliability of the 3000A series, offering an updated user interface accessed through a large 7" capacitive touch screen to enable advanced functionality, including a built-in procedure mode and inbuilt connection prompts to minimise errors.
Procedures can be loaded into the 4000 Series via USB memory stick, with results stored for integration back into ProCal software. The 4000 Series also provides USB printer connectivity as standard, supporting a wide range of PCL compatible printers. Reports can be printed directly from the calibrator - ideal for in-situ or on-site applications.
- 0 - 1000V DC / AC Voltage
- 0 - 30A DC / AC Current
- Variable Resistance up to 1GOhm
- Variable Capacitance to 100mF
- 1Hz - 10MHz Frequency
- AC current maximum frequency 30kHz
- Range of external accessories to increase workload
- USB and GPIB interface fitted as standard
- Removable Handles
HIGHLIGHTS
Traceable Self-Verification Functionality
To maintain confidence in your equipment, simply connect an 8000 series digital multimeter to the rear of the unit and enter 'self-calibration mode'. The 4000 series will then proceed to measure its outputs automatically and generate a test report which can be exported to a USB memory stick for analysis on a computer, and print a test report via a USB printer for maintaining records.
SOFTWARE COMPATABILITY
As with all Transmille products, compatibility with ProCal calibration software is guaranteed. Existing procedures will not need to be re-written due to Transmille's unique implementation of flexible standards support where procedures are written around the UUT not the standard.
PRODUCT RANGE
DC VOLTAGE
Best 1 Year Total Accuracy
0 - ±1025V
±8ppm
0 - ±1025V
±15ppm
DC CURRENT
Best 1 Year Total Accuracy
0 - 30A
±50ppm
0 - 30A
±50ppm
AC VOLTAGE
Best 1 Year Total Accuracy
20mV - 1025V, 10Hz - 1MHz
±0.015%
20mV - 1000V, 10Hz - 500kHz
±0.015%
AC CURRENT
Best 1 Year Total Accuracy
20uA - 30A, 10Hz - 30kHz
0.04%
20uA - 30A, 10Hz - 30kHz
0.04%
RESISTANCE (PASSIVE)
Best 1 Year Total Accuracy
0 - 1 GOhms
18ppm
0 - 1 GOhms
40ppm
FREQUENCY
Best 1 Year Total Accuracy
1Hz - 10MHz
1ppm
1Hz - 10MHz
20ppm (1ppm Option)
TEMPERATURE (THERMOCOUPLE)
Best 1 Year Total Accuracy
J / K / T / R / S / B / U / N / E / L / U / C / 10uV°C
±0.09°C
J / K / T / R / S / B / U / N / E / L / U / C / 10uV°C
±0.09°C
RESISTANCE (SIMULATED)
Best 1 Year Total Accuracy
0 Ohms - 1 GOhm
100ppm
0 Ohms - 1 GOhm
100ppm
Resources
4000 SERIES
PWRDDS / ProWave User Manual
4015 Extended Specifications V1.2
4010 Extended Specifications V1.5
4000 Series Brochure - English
4000 Series Operation Manual
4010 Example Certificate
Transmille Product Guide
Transmille Product Matrix
Transmille Product Guide 2015/16 (English)
Transmille Product Guide 2015/16 (Japanese)
Transmille Warranty
Transmille Warranty
VIDEOS & DEMOS
4000 SERIES - DIRECT OHMS SELECTION
In this short video we demonstrate the latest updates to the 4000 series. The addition of new function keys enable direct access to the decade passive resistors enabling outputs to be directly accessed with a single touch of the screen.
4000 Series - Procedure Mode
Demonstration of the built-in procedure mode using a typical multimeter.
Options & Accessories
External
A comprehensive set of test leads providing every connection required for typical measurements
External
A comprehensive set of test leads providing every connection required for typical measurements
A superior thermocouple simulation/measurement option, using a unique external adapter.
- Offers fast and accurate calibration of thermocouple meters
- Uses an innovative external measurement of cold junction temperature for ultimate accuracy
- Utilising a thermocouple plug removes the requirement for expensive thermocouple compensation cable
External
Calibrate clamp meters at up to 1500A using the EA002 clamp meter. A unique design enables clamps of all sizes to be used, while minimising errors due to alignment
- Calibrates clamp meters up to 1500A (30A input)
- 2/10/50 Turn Coils
- High accuracy AC/DC design, with minimal errors due to alignment
- Wide range of clamp sizes covered, from 10mm jaw diameter to larger clamps
- Alignment table included for accurate and repeatable readings
Instantly add the ability to calibrate tachometers to 60,000 RPM by adding the EA003 to your calibrator
- High-intensity LED light source
- Direct keyboard input in RPM
- Control via ProCal for fully automated calibration
- Output range from 60 to 60,000 RPM
Adds measurement capability to 1pA resolution, and measures high value resistors to 1TOhm using the calibrator as a precision DC voltage source
- Accurate current measurement down to 1pA resolution
- Ideal for high value resistance measurements up to 1 TOhm
- High resistance measurement voltages up to 1000V
- 5 current measurement rnages from 10nA to 100uA
- Control directly from the calibrator front panel or use with ProCal software
External
As multimeters add more accurate low current ranges, traditional multi-product calibrators lack the precision and noise level for accurate calibration. With the EA013 pA source adapter, calibration of these instruments becomes simple
- Ideal for calibration of electrometer instruments
- Source accurate current down to picoamp levels
- Low open circuit compliance voltage
- Safe to use on sensitive input circuits
- Controlled directly from the calibrator front panel or via supplied software
- Compatible with ProCal for full measurement automation
External
Extend your laboratory's capabilities with the ability to calibrate torque screwdrivers and much more
Combining Transmille's most popular options, the EA015 provides a cost-effective method of increasing the workload coverage of Transmille calibrators
- Insulation Testers
- Continuity Testers
- Optical Tachometers
- Thermocouple Meters
- Clamp Meters
- Source functions of process control meters
Measure environmental factors both on site and in the laboratory
- Humidity measurement from 10% to 90%
- Temperature measurement from 0°C to 50°C
Automate calibration of 4 channel oscilloscopes with automised switching of channels with the EA017 adapter
- 4 Output channels for automating oscilloscope calibration
- Minimises lead changing when calibrating oscilloscopes
- Choose between direct or buffered outputs for amplitude calibration
Calibrate low value high current shunts up to 100A and clamp meters up to 2000A using the EA3012A Transconductance Amplifier
- 100 DC/70A AC up to 400Hz
- Stackable for higher currents
- Low-noise ultra linear MOSFET technology
- Controlled directly via front panel of calibrator
- Automation through ProCal software
- Ideal for calibrating high current shunts, meters and clamp meters