4000 Series
Advanced Multiproduct Calibrator
The 4000 Series is aimed at laboratories, manufacturers and design facilities requiring a wide range of outputs with accuracies up to 8ppm.
The 4000 Series builds on the trusted reliability of the 3000A series, offering an updated user interface accessed through a large 7" capacitive touch screen to enable advanced functionality, including a built-in procedure mode and inbuilt connection prompts to minimise errors.
Procedures can be loaded into the 4000 Series via USB memory stick, with results stored for integration back into ProCal software. The 4000 Series also provides USB printer connectivity as standard, supporting a wide range of PCL compatible printers. Reports can be printed directly from the calibrator - ideal for in-situ or on-site applications.
- 0 - 1000V DC / AC Voltage
- 0 - 30A DC / AC Current
- Variable Resistance up to 1GOhm
- Variable Capacitance to 100mF
- 1Hz - 10MHz Frequency
- AC current maximum frequency 30kHz
- Range of external accessories to increase workload
- USB and GPIB interface fitted as standard
- Removable Handles
HIGHLIGHTS
Traceable Self-Verification Functionality
To maintain confidence in your equipment, simply connect an 8000 series digital multimeter to the rear of the unit and enter 'self-calibration mode'. The 4000 series will then proceed to measure its outputs automatically and generate a test report which can be exported to a USB memory stick for analysis on a computer, and print a test report via a USB printer for maintaining records.
SOFTWARE COMPATABILITY
As with all Transmille products, compatibility with ProCal calibration software is guaranteed. Existing procedures will not need to be re-written due to Transmille's unique implementation of flexible standards support where procedures are written around the UUT not the standard.
PRODUCT RANGE
DC VOLTAGE
Best 1 Year Total Accuracy
0 - ±1025V
±8ppm
0 - ±1025V
±15ppm
DC CURRENT
Best 1 Year Total Accuracy
0 - 30A
±50ppm
0 - 30A
±50ppm
AC VOLTAGE
Best 1 Year Total Accuracy
20mV - 1025V, 10Hz - 1MHz
±0.015%
20mV - 1000V, 10Hz - 500kHz
±0.015%
AC CURRENT
Best 1 Year Total Accuracy
20uA - 30A, 10Hz - 30kHz
0.04%
20uA - 30A, 10Hz - 30kHz
0.04%
RESISTANCE (PASSIVE)
Best 1 Year Total Accuracy
0 - 1 GOhms
18ppm
0 - 1 GOhms
40ppm
FREQUENCY
Best 1 Year Total Accuracy
1Hz - 10MHz
1ppm
1Hz - 10MHz
20ppm (1ppm Option)
TEMPERATURE (THERMOCOUPLE)
Best 1 Year Total Accuracy
J / K / T / R / S / B / U / N / E / L / U / C / 10uV°C
±0.09°C
J / K / T / R / S / B / U / N / E / L / U / C / 10uV°C
±0.09°C
RESISTANCE (SIMULATED)
Best 1 Year Total Accuracy
0 Ohms - 1 GOhm
100ppm
0 Ohms - 1 GOhm
100ppm
Resources
4000 SERIES
PWRDDS / ProWave User Manual
4015 Extended Specifications V1.2
4010 Extended Specifications V1.5
4000 Series Brochure - English
4000 Series Operation Manual
4010 Example Certificate
Transmille Product Guide
Transmille Product Matrix
Transmille Product Guide 2015/16 (English)
Transmille Product Guide 2015/16 (Japanese)
Transmille Warranty
Transmille Warranty
VIDEOS & DEMOS
4000 SERIES - DIRECT OHMS SELECTION
In this short video we demonstrate the latest updates to the 4000 series. The addition of new function keys enable direct access to the decade passive resistors enabling outputs to be directly accessed with a single touch of the screen.
4000 Series - Automated Verification
An example of the automated verification functionality using a Transmille 8081 precision multimeter.
4000 Series - Procedure Mode
Demonstration of the built-in procedure mode using a typical multimeter.
Options & Accessories
Increase your laboratory capability with the ability to calibrate power supplies up to 3A/63V
- Measures voltage up to 63V
- Active current load to 3A
- Calculates output resistance of a power supply for complete calibration
Increase your laboratories workload coverage to include high current power supplies with up to 60A/100V outputs.
- Easy to use, low cost solution
- Accurate, stable electronic load