4010

Advanced Multiproduct Calibrator

  • 0 – 1000V DC / AC Voltage
  • 0 – 30A DC / AC Current
  • Variable Resistance up to 1GOhm
  • Variable Capacitance to 100mF
  • 1Hz – 10MHz Frequency
  • AC current maximum frequency 30kHz
  • Range of external accessories to increase workload
  • USB and GPIB interface fitted as standard
  • Removable Handles

ASK AN EXPERT

Information

Description

SOFTWARE COMPATIBILITY

As with all Transmille products, compatibility with ProCal calibration software is guaranteed. Existing procedures will not need to be re-written due to Transmille’s unique implementation of flexible standards support where procedures are written around the UUT not the standard.

4010 Specifications

4010 Specifications

DC VOLTAGE

Best 1 Year Total Accuracy

0 - ±1025V
±8ppm

DC CURRENT

Best 1 Year Total Accuracy

0 - 30A
±50ppm

AC VOLTAGE

Best 1 Year Total Accuracy

20mV - 1025V, 10Hz - 1MHz
±0.015%

AC CURRENT

Best 1 Year Total Accuracy

20uA - 30A, 10Hz - 30kHz
0.04%

RESISTANCE (PASSIVE)

Best 1 Year Total Accuracy

0 - 1 GOhms
18ppm

FREQUENCY

Best 1 Year Total Accuracy

1Hz - 10MHz
1ppm

TEMPERATURE (THERMOCOUPLE)

Best 1 Year Total Accuracy

J / K / T / R / S / B / U / N / E / L / U / C / 10uV°C
±0.09°C

RESISTANCE (SIMULATED)

Best 1 Year Total Accuracy

0 Ohms - 1 GOhm
100ppm

4010 Resources
Transmille Product Guide
Transmille Warranty

Transmille Warranty

Videos & Demos

Videos & Demos

4000 SERIES - DIRECT OHMS SELECTION

In this short video we demonstrate the latest updates to the 4000 series. The addition of new function keys enable direct access to the decade passive resistors enabling outputs to be directly accessed with a single touch of the screen.

4000 Series - Automated Verification

An example of the automated verification functionality using a Transmille 8081 precision multimeter.

4000 Series - Procedure Mode

Demonstration of the built-in procedure mode using a typical multimeter.

Options & Accessories

Increase your laboratory capability with the ability to calibrate power supplies up to 3A/63V

  • Measures voltage up to 63V
  • Active current load to 3A
  • Calculates output resistance of a power supply for complete calibration

Increase your laboratories workload coverage to include high current power supplies with up to 60A/100V outputs.

  • Easy to use, low cost solution
  • Accurate, stable electronic load
  • Minimises equipment required for calibration

Internal

Option FRQ

For calibration of high accuracy frequency counters, a 1ppm high stability frequency output is available on 3000/4000 only.

Internal

Option GPIB

Additional GPIB / IEEE 488 interface for connecting into existing systems

Internal

Option IND

For full calibration of LCR meters, an inductance output is required. Option IND adds 8 fixed inductance values to enable complete calibration, available on 3000/4000 only.

Internal

Option PWRDDS

Option PWRDDS expands on the functionality of PWRSINE by adding the ability to simulate harmonics, distortion, dropouts and flicker for calibration of power meters with power quality functions,available on 3000/4000 only.

Internal

Option PWRSINE

Enables calibration of power and wattmeters, with a dynamically controlled phase relationship between voltage and current outputs available on 3000/4000 only.

Internal

Option SCP350

Providing calibration for oscilloscopes to 350Mhz bandwidth available on 3000/4000 only.

Internal

Option SCP600

Providing calibration for oscilloscopes to 600Mhz bandwidth available on 3000/4000 only.

For integration in to mobile test systems, or permanent installation in a laboratory, a 19" rack system is provided

Internal

SIMRC

In addition to passive resistance fitted as standard, option SIMRC adds variable resistance and simulated capacitance outputs available on 3000/4000 only.

An external pressure module for use with Transmille products, designed to extend capabilities to 1 PSI