AC/DC Shunts

Precision References And Standards

Transmille offer a set of current shunts enabling measurement of current from 1mA through to 100A. Each shunt develops 0.7V at nominal full scale, enabling a wide range of multimeters to be used without loss of resolution due to changing range.

  • Shunt values for measurements between 1mA to 100A
  • AC/DC differences from 1ppm
  • Simplifies precision calibration of calibrators and current sources
  • Low inductance & capacitance flat frequency response
  • From DC to 30kHz
  • Can be used with a precision multimeter or an AC measurement standard
More Info Global Distributors

3000HR Precision Resistance Standard

Precision References and Standards

  • Electrometer currents to 10nA
  • Traceable to 1 GOhm standard
  • Resistance from 1 Mohm to 100 Gohm
More Info Global Distributors

3000HR

3000RS Precision Resistance Standard

Precision References and Standards

  • Decade resistances from 1 Ohm to 10MOhm
  • Annual stabilities of better than 5ppm
  • Temperature co-efficients as low as 0.1ppm/°C
  • Precision decade resistance reference
More Info Global Distributors

3000RS

3000ZR Precision Zener Reference

Precision References & Standards

  • 4 Banks of 10V and 1.018V outputs
  • Stability of better than 2ppm/year
  • Internal battery backup for transportation
More Info Global Distributors

3000ZR

3000AC Voltage Reference

Precision References and Standards

  • Calculable AC voltage reference source
  • Traceable to any DC voltage multimeter with suitable accuracies
  • Accuracy in the order of 10ppm
  • AC voltage with frequency to 1kHz
More Info Global Distributors

3000AC

3000CS Precision Current Shunt

Precision References & Standards

  • Precision current shunt array
  • 1 year stability of up to 5ppm
  • Temperature coefficients of less than 0.6ppm/°C
  • Values 10mA through to 10A
  • 4-Wire PT100 Output
More Info Global Distributors

3000CS

References & Standards

3000AC Voltage Reference

Precision References and Standards

  • Calculable AC voltage reference source
  • Accuracy in the order of 10ppm
  • Traceable to any DC voltage multimeter with suitable accuracies
  • AC voltage with frequency to 1kHz

References & Standards

3000CS Precision Current Shunt

Precision References & Standards

  • Precision current shunt array
  • Values 10mA through to 10A
  • 1 year stability of up to 5ppm
  • 4-Wire PT100 Output
  • Temperature coefficients of less than 0.6ppm/°C

References & Standards

3000HR Precision Resistance Standard

Precision References and Standards

  • Electrometer currents to 10nA
  • Resistance from 1 Mohm to 100 Gohm
  • Traceable to 1 GOhm standard

References & Standards

3000RS Precision Resistance Standard

Precision References and Standards

  • Decade resistances from 1 Ohm to 10MOhm
  • Temperature co-efficients as low as 0.1ppm/°C
  • Annual stabilities of better than 5ppm
  • Precision decade resistance reference

References & Standards

3000ZR Precision Zener Reference

Precision References & Standards

  • 4 Banks of 10V and 1.018V outputs
  • Internal battery backup for transportation
  • Stability of better than 2ppm/year

References & Standards

AC/DC Shunts

PRECISION REFERENCES AND STANDARDS

  • Shunt values for measurements between 1mA to 100A
  • Low inductance & capacitance flat frequency response
  • AC/DC differences from 1ppm
  • From DC to 30kHz
  • Simplifies precision calibration of calibrators and current sources
  • Can be used with a precision multimeter or an AC measurement standard