Calibration Services

AC Current Calibration

  • 17025 Accredited AC Voltage calibration services from 2mV to 28 kV
  • 10Hz to 1MHz capability depending upon level

References & Standards

AC/DC Shunts

PRECISION REFERENCES AND STANDARDS

  • Shunt values for measurements between 1mA to 100A
  • Low inductance & capacitance flat frequency response
  • AC/DC differences from 1ppm
  • From DC to 30kHz
  • Simplifies precision calibration of calibrators and current sources
  • Can be used with a precision multimeter or an AC measurement standard

Calibration Services

Resistance Calibration

  • 17025 Accredited Resistance calibration from 100 uOhm to 1 TOhm, with a wide capability with uncertainties lower than 1 ppm

The BreakD option allows the 3200 to calibrate both voltage output and current measurements of HiPot and Breakdown testers up to 12kV AC/DC

  • 4 voltage ranges: 3kV & 12kV, AC and DC Voltage
  • 9 Load Resistors/Current Ranges: 50kOhms (20mA) to 20MOhms (20uA) @ 1kV

Calibration Services

Capacitance Calibration

  • Accredited measurements from 10pF to 10uF
  • Measurement at 1kHz

A superior thermocouple simulation/measurement option, using a unique external adapter.

  • Offers fast and accurate calibration of thermocouple meters
  • Uses an innovative external measurement of cold junction temperature for ultimate accuracy
  • Utilising a thermocouple plug removes the requirement for expensive thermocouple compensation cable
 

Calibration Services

Inductance Calibration

  • 17025 Accredited Inductance calibration from 10 uH to 1 H at 1 kHz, with the capability to measure and generate up to 100 H for traceable calibrations

Calibrate clamp meters at up to 1500A using the EA002 clamp meter. A unique design enables clamps of all sizes to be used, while minimising errors due to alignment

  • Calibrates clamp meters up to 1500A (30A input)
  • 2/10/50 Turn Coils
  • High accuracy AC/DC design, with minimal errors due to alignment
  • Wide range of clamp sizes covered, from 10mm jaw diameter to larger clamps
  • Alignment table included for accurate and repeatable readings

Calibration Services

Time & Frequency Calibration

  • 17025 Accredited Time & Frequency measurement and generation from 10 mHz to 1 GHz

Instantly add the ability to calibrate tachometers to 60,000 RPM by adding the EA003 to your calibrator

  • High-intensity LED light source
  • Direct keyboard input in RPM
  • Control via ProCal for fully automated calibration
  • Output range from 60 to 60,000 RPM

Calibration Services

Temperature Calibration

  • 17025 Accredited Simulation of PRT / RTD and Thermocouple Temperature

Adds measurement capability to 1pA resolution, and measures high value resistors to 1TOhm using the calibrator as a precision DC voltage source

  • Accurate current measurement down to 1pA resolution
  • Ideal for high value resistance measurements up to 1 TOhm
  • High resistance measurement voltages up to 1000V
  • 5 current measurement rnages from 10nA to 100uA
  • Control directly from the calibrator front panel or use with ProCal software

As multimeters add more accurate low current ranges, traditional multi-product calibrators lack the precision and noise level for accurate calibration. With the EA013 pA source adapter, calibration of these instruments becomes simple

  • Ideal for calibration of electrometer instruments
  • Source accurate current down to picoamp levels
  • Low open circuit compliance voltage
  • Safe to use on sensitive input circuits
  • Controlled directly from the calibrator front panel or via supplied software
  • Compatible with ProCal for full measurement automation

Extend your laboratory's capabilities with the ability to calibrate torque screwdrivers and much more

Combining Transmille's most popular options, the EA015 provides a cost-effective method of increasing the workload coverage of Transmille calibrators

  • Insulation Testers
  • Continuity Testers
  • Optical Tachometers
  • Thermocouple Meters
  • Clamp Meters
  • Source functions of process control meters

Measure environmental factors both on site and in the laboratory

  • Humidity measurement from 10% to 90%
  • Temperature measurement from 0°C to 50°C

Automate calibration of 4 channel oscilloscopes with automised switching of channels with the EA017 adapter

  • 4 Output channels for automating oscilloscope calibration
  • Minimises lead changing when calibrating oscilloscopes
  • Choose between direct or buffered outputs for amplitude calibration

Enables calibration of source functions of Process Control instruments including voltage, current and resistance.

  • Extends workload of 1000 Series Calibrators
  • Measure source functions from process control instruments
  • Voltages up to 30V
  • Currents up to 30A
  • 2 and 4 wire resistance up to 10 kOhms
  • 24V loop supply

Calibrate low value high current shunts up to 100A and clamp meters up to 2000A using the EA3012A Transconductance Amplifier

  • 100 DC/70A AC up to 400Hz
  • Stackable for higher currents
  • Low-noise ultra linear MOSFET technology
  • Controlled directly via front panel of calibrator
  • Automation through ProCal software
  • Ideal for calibrating high current shunts, meters and clamp meters