AC/DC Shunts

Precision References And Standards

Transmille offer a set of current shunts enabling measurement of current from 1mA through to 100A. Each shunt develops 0.7V at nominal full scale, enabling a wide range of multimeters to be used without loss of resolution due to changing range.

  • Shunt values for measurements between 1mA to 100A
  • AC/DC differences from 1ppm
  • Simplifies precision calibration of calibrators and current sources
  • Low inductance & capacitance flat frequency response
  • From DC to 30kHz
  • Can be used with a precision multimeter or an AC measurement standard
More Info Global Distributors

3000HR Precision Resistance Standard

Precision References and Standards

  • Electrometer currents to 10nA
  • Traceable to 1 GOhm standard
  • Resistance from 1 Mohm to 100 Gohm
More Info Global Distributors

3000HR

3000RS Precision Resistance Standard

Precision References and Standards

  • Decade resistances from 1 Ohm to 10MOhm
  • Annual stabilities of better than 5ppm
  • Temperature co-efficients as low as 0.1ppm/°C
  • Precision decade resistance reference
More Info Global Distributors

3000RS

3000ZR Precision Zener Reference

Precision References & Standards

  • 4 Banks of 10V and 1.018V outputs
  • Stability of better than 2ppm/year
  • Internal battery backup for transportation
More Info Global Distributors

3000ZR

3000AC Voltage Reference

Precision References and Standards

  • Calculable AC voltage reference source
  • Traceable to any DC voltage multimeter with suitable accuracies
  • Accuracy in the order of 10ppm
  • AC voltage with frequency to 1kHz
More Info Global Distributors

3000AC

3000CS Precision Current Shunt

Precision References & Standards

  • Precision current shunt array
  • 1 year stability of up to 5ppm
  • Temperature coefficients of less than 0.6ppm/°C
  • Values 10mA through to 10A
  • 4-Wire PT100 Output
More Info Global Distributors

3000CS

References & Standards

3000AC Voltage Reference

Precision References and Standards

  • Calculable AC voltage reference source
  • Accuracy in the order of 10ppm
  • Traceable to any DC voltage multimeter with suitable accuracies
  • AC voltage with frequency to 1kHz

References & Standards

3000CS Precision Current Shunt

Precision References & Standards

  • Precision current shunt array
  • Values 10mA through to 10A
  • 1 year stability of up to 5ppm
  • 4-Wire PT100 Output
  • Temperature coefficients of less than 0.6ppm/°C

References & Standards

3000HR Precision Resistance Standard

Precision References and Standards

  • Electrometer currents to 10nA
  • Resistance from 1 Mohm to 100 Gohm
  • Traceable to 1 GOhm standard

References & Standards

3000RS Precision Resistance Standard

Precision References and Standards

  • Decade resistances from 1 Ohm to 10MOhm
  • Temperature co-efficients as low as 0.1ppm/°C
  • Annual stabilities of better than 5ppm
  • Precision decade resistance reference

References & Standards

3000ZR Precision Zener Reference

Precision References & Standards

  • 4 Banks of 10V and 1.018V outputs
  • Internal battery backup for transportation
  • Stability of better than 2ppm/year

References & Standards

AC/DC Shunts

PRECISION REFERENCES AND STANDARDS

  • Shunt values for measurements between 1mA to 100A
  • Low inductance & capacitance flat frequency response
  • AC/DC differences from 1ppm
  • From DC to 30kHz
  • Simplifies precision calibration of calibrators and current sources
  • Can be used with a precision multimeter or an AC measurement standard

Internal

Option FRQ

For calibration of high accuracy frequency counters, a 1ppm high stability frequency output is available on 3000/4000 only.

Internal

Option GPIB

Additional GPIB / IEEE 488 interface for connecting into existing systems

Internal

Option IND

For full calibration of LCR meters, an inductance output is required. Option IND adds 8 fixed inductance values to enable complete calibration, available on 3000/4000 only.

Internal

Option INS

Enables calibration of insulation testers up to 1000V/1GOhm, and continuity testers with up to 320mA testing current.available on 1000 series only.

Internal

Option PRT

Precision 4 Wire PRT output for guaranteed compatibility with both DC meters and AC bridges available on 3000/4000 only.

Internal

Option PWRDDS

Option PWRDDS expands on the functionality of PWRSINE by adding the ability to simulate harmonics, distortion, dropouts and flicker for calibration of power meters with power quality functions,available on 3000/4000 only.